Free England Fire Safety Logbook Template
A printable checklist and a CSV download written for England. Bring your own dates. Nothing here is a prescribed form.
The blank below is FireCert Clock's own checklist for a fire safety log in England. It is not a Home Office form, not a council form, and not a copy of any British Standard. Download the same rows as CSV: England fire safety logbook CSV
Print the table or open the file in a spreadsheet. Fill last done, the next date you accept, the person, and the result. If you later create a building with England selected, confirm those dates in the account so reminders use them. The CSV itself does not email anyone.
Checklist
| Check | Interval you set | What to write |
|---|---|---|
| Responsible Person | Not a recurring test | Name and contact on the building profile |
| Fire risk assessment review | Days you choose | Last review, why you reviewed, open actions. Not an annual renewal |
| Communal fire door check | At least every 3 months where regulation 10 applies | Date, person, self closers. England, residential, over 11 metres |
| Flat entrance door check | At least every 12 months, best endeavours | Date, and access attempts if a flat was not reached |
| Lifts for firefighters | Monthly where the high rise residential duty applies | Date and faults |
| Firefighting equipment | Monthly in that same high rise case | Date, and a fault still open after 24 hours |
| Weekly alarm test | Your interval | BS 5839-1 is a name only. Do not treat this row as the standard |
| Monthly emergency lighting | Your interval | BS 5266 is a name only |
| Full duration emergency lighting test | Your interval | BS 5266 is a name only |
Leave a row blank when the building is outside that duty. A building under 11 metres does not grow a quarterly communal door row because a template mentioned one. The account hides those checks until the profile matches.
Sources to read before you rely on a row
Fire risk assessments, including regular review: https://www.gov.uk/workplace-fire-safety-your-responsibilities/fire-risk-assessments
The Fire Safety (England) Regulations 2022, in force 23 January 2023, England only: https://www.legislation.gov.uk/uksi/2022/547
Home Office guide: https://www.gov.uk/government/publications/fire-safety-england-regulations-2022
Penalties for serious offences, unlimited fines and up to 2 years' imprisonment: https://www.gov.uk/workplace-fire-safety-your-responsibilities/enforcement-appeals-and-penalties
The narrative page is the England fire safety logbook. Door timing is England fire door checks. The review habit is the fire risk assessment review checklist.
A paper log aimed at inspectors who still want a book in the cabinet, without the England 2022 split, remains the fire safety log book template.
Upload your last logbook and we fill it in for you
A filled logbook can be uploaded later so the dates are suggested for review. The steps are on upload an England logbook.
A blank log is not the Fire Safety Order
The downloadable England log is a layout for the checks you have decided apply. It is not a government form. GOV.UK, read 9 Nov 2026, requires a written fire risk assessment and a regular review, and the 2022 regulations add dated checks for some residential buildings. The blank follows those topics so a managing agent can keep one book. It does not decide that your building is over 11 metres, and it does not set a review month. https://www.gov.uk/workplace-fire-safety-your-responsibilities/fire-risk-assessments
Use the CSV or the printed sections as a starting record: responsible person, height band, residential common parts, the review you scheduled, door checks where they apply, and lift checks where the building is high rise. Replace any row that does not apply. A commercial unit should not carry a flat entrance door section just because the template mentions one.
What the blank is for
| Feature | Use the blank | Use a different document |
|---|---|---|
| Daily record | Dates, names, defects, and actions you type | The written fire risk assessment itself, which article 9 requires |
| Residential block over 11 metres | Communal door lines and flat entrance lines | An authority form, if the fire and rescue service has told you to use one |
| High rise residential | A place to note the monthly lift and equipment check, and whether a fault passed 24 hours | The actual notice you send the fire and rescue service. The blank does not send it |
| Assessment review | A line for the interval you chose | A claim that the Order renews on a birthday |
The CSV linked from the log includes a fire risk assessment review row so the interval is visible. Confirm that interval in the product. Leave it blank in the product if the CSV was only a draft.
How to track after you print
Print or save the blank. Fill it after the check, not before. Upload the finished file on upload an England logbook and accept only dates that match the ink. The duties are on the England fire safety logbook. The review is risk assessment review. Doors are fire door checks.
GOV.UK's enforcement page, read 9 Nov 2026, states fines up to £5,000 for minor cases and unlimited fines with up to 2 years in prison for major cases. A template does not reduce that. https://www.gov.uk/workplace-fire-safety-your-responsibilities/enforcement-appeals-and-penalties
Can one template cover a portfolio?
Print one copy per building. A single book for seven addresses hides which responsible person and which height band applied. The account can still show every building on one overdue list.
Filling the blank after the check, not before
Write the responsible person and the building facts first: height band, and whether there are residential common parts. Cross out the communal door lines if the building is not a multi occupied residential building over 11 metres. Cross out the flat entrance lines for the same reason. Cross out the firefighter lift lines unless the building is at least 18 metres or at least 7 storeys. GOV.UK's overview, read 9 Nov 2026, is the source of those limits. Leave the risk assessment review line, and write the interval you chose, or leave the interval blank in the product so no countdown pretends the Order named a month. Upload the finished sheets. Accept a date only when it matches what you wrote. The CSV is a FireCert Clock layout. It is not a Home Office form.
FAQ
Is the CSV an official logbook?
No. It is a FireCert Clock blank. The Home Office and GOV.UK publish the duties and the guides. Use the records your fire and rescue authority or your own policy already accepts if they differ. Do not present the CSV as theirs.
Can I change the intervals on the CSV?
Yes. The interval column is blank on purpose. Type the gap you use. In the account, optional alarm and lighting rows are editable the same way.
Does downloading the file create an account?