FireCert Clock

Fire dates for HSE teams

Corporate health and safety teams inherit buildings they do not manage day to day. The miss is a date that differs by country and by address.

Property and strata managers keep a log per building.

An HSE or EHS team is asked for fire evidence across offices, warehouses, and shops that do not share one legal rule. A single annual reminder for "fire" hides the building whose certificate expires in a different month, and it hides the building that has no annual certificate at all. Fire safety compliance software for multiple sites has to keep those clocks apart.

FireCert Clock stores one site per address. The overdue list covers every site. Presets propose a date only when the official rule is a single interval you can count. You confirm it. The product does not replace the local competent person and it does not file with the authority.

Where the portfolio sits

Property, strata, and managing agent workflows are on property managers.

A portfolio workflow

Create a site for each address and set the jurisdiction before you import assets. Upload the last local filing when auto fill is available for that jurisdiction, then accept or edit each suggestion. Dates that the rule does not fix stay empty until someone on the team types them. Export the activity log when an auditor asks who confirmed a date. Seats and site caps are the published plans on pricing.

What an auditor asks before anyone opens a binder

An HSE or EHS team is usually asked three things: which sites are overdue, who confirmed the date, and where the signed filing is. The buildings may be offices, warehouses, and shops the team does not manage day to day. The local rule still belongs to the address. A single "annual fire" reminder hides both the building whose certificate expires in another month and the building that has no annual certificate at all.

FireCert Clock keeps one site per address and one overdue list for the account. The activity log records the confirmation. That is the audit trail. The product does not replace the local competent person, does not lodge with the authority, and does not sign the form.

Portfolio map

Open the country page for the rule, then the upload page when you have last year's file.

FeatureNSWVictoriaSouth AustraliaNew ZealandEnglandSingapore
Legal role on the filingBuilding owner, or an authorised agent. The practitioner does not make the owner's declarationBuilding owner. An agent may complete the report. The owner signsBuilding owner provides the annual proofBuilding owner, or the owner's agent, signs Form 12Responsible person, who may be the employer, owner, landlord, occupier, or managing agentOwner or occupier of a designated building
Clock the team should storeAnnual statement each year, plus supplementary dates from the scheduleReport inside the 28 days before the anniversaryForm 3 not later than 60 business days after the calendar year, unless exemptForm 12 on the compliance schedule anniversary, with every Form 12ARisk assessment reviewed regularly. You set the intervalCertificate expiry you type, renewal at least two months before, plus the annual inspection
HSE pageNSWVictoriaSouth AustraliaNew ZealandEnglandSingapore
UploadAFSSESM reportESP formBWoFLogbookFire Certificate

UAE sites stay on intervals you type: UAE fire dates for HSE teams. Managing agents use property managers.

Sources read 9 Nov 2026: NSW Planning fire safety certification, the Victorian essential safety measures guide, PlanSA Form 3, MBIE on the building warrant of fitness, GOV.UK responsible person duties, and SCDF on the Fire Certificate.

Calculation: 36 sites and four people who need a login

Labelled from the published caps on pricing. No price here is new.

Thirty six sites are past the Starter cap of 10 and inside the Pro cap of 50. Four seats are inside the Pro seat cap of 5 and past the Starter seat cap of 1. Pro has no asset cap, so a large measure list does not by itself force another plan. The Pro monthly price is $79. The yearly price is $790, which is $79 times 10. API and CSV export are not in the Pro column. They start on Business at $149 a month, yearly $1,490, which is $149 times 10, with 15 seats and no site cap. Use Business when the site count passes 50 or the people who need a login pass 5.

The overdue list is still one list. Each row still names one site. Export the activity log when the auditor asks who accepted a date. Free accounts include 20 document reads a month. A read that fails, or a file past 12 pages, leaves the file stored and the fields for you to type.

What the team should not pretend the software did

It did not inspect the building. It did not decide that England's assessment renews on a birthday. GOV.UK says review regularly. It did not decide that every Singapore certificate issued after 1 April 2026 is still a 12 month certificate. SCDF says 36 months unless otherwise stated, for validity that starts on or after that date. It did not file the 24 hour firefighter lift fault with an English fire and rescue authority. The log can show the fault is open. You send the report.

Can head office confirm a date the site team has not checked?

You can, and the activity log will show that you did. Confirm only a date you have matched to the filing. Accept all leaves a saved confirmed date alone.

Is the CSV the fire risk assessment?

No. England's written assessment stays the document the responsible person holds. The export is the register of dates and actions you chose to track.

FAQ

Is this a substitute for a fire risk assessment?

No. England's assessment review is a date you set. Other countries' certificates are records you confirm. The assessment itself is done by a competent person.

Can head office see every overdue building?

The overdue list is account wide. Each row still belongs to one site.

Set up a site free

Set up a site free