Guides and references
Rules, templates and country guides
Country guides, free templates and comparisons for the people who run the visits. A jurisdiction preset is a dated guide for one building. You confirm every date.
Who it is for, and who it is not for
FireCert Clock is fire-inspection due-date software for the people who already do the visits. You add a building, add the assets inside it, and upload the report after the work. The product emails you 30 days before the next due date, then again at 14 days, 7 days, 3 days, and on the final day. It does not dispatch technicians, write invoices, or certify a system. It keeps the date and the file so a missed month shows up on your list before it shows up in an inspection.
Facilities teams use it for the building they already occupy: extinguishers, the alarm, sprinklers, emergency lights, doors, hoods, and pumps, each with its own interval. Contractors use it for client sites when the office still runs a binder or a spreadsheet and the field work already produces a PDF. Both groups fail the same way. The visit happened. The next date lived in someone's head, or in a van that is on another job.
If you service a handful of buildings, or you look after one site's extinguishers and lights, FireCert Clock is built for you. It is a tracker, not a dispatch or invoicing suite. It is a poor fit if you need mobile forms on every tablet, same-day quotes, and invoicing in the same login. That is a field suite. The category split is on best fire inspection software. Moving a spreadsheet you already keep is the switch form.
A week on a shared clinic, and the people who open the list, is on how it works.
The date lives in the other van
An extinguisher was due last month. The log book is in the other van. The building manager is asking for proof. You find out from a failed inspection, not from your own list.
FireCert Clock is the due-date list. Sites, assets, last service, next due. Five notices: 30 days, 14 days, a week, three days, one day. After the visit, upload the report. On Starter, FireCert Clock reads the dates off the report and you confirm them.
How a due date is computed
The next due date is the last service date plus the interval stored on the asset. That interval is a preset already in the product, or a number you type when the local rule differs. Adding the days is calendar arithmetic. A 30 day preset moves a 6 March service to 5 April. A 365 day preset moves a 2 June 2026 service to 2 June 2027.
Day counts already on the presets:
- Portable extinguisher monthly visual, NFPA 10: 30 days. Annual maintenance by a qualified person: 365 days. Six-year internal maintenance: 2190 days. Five-year hydrostatic test for water, wet chemical, foam, and CO2: 1825 days. Twelve-year hydrostatic test for stored-pressure dry chemical and halogenated agents: 4380 days.
- Fire alarm annual inspection and test, NFPA 72: 365 days. Semiannual visuals that follow the quarterly preset times two: 182 days. Unmonitored control unit visual: 7 days.
- Sprinkler quarterly tasks, NFPA 25: 91 days. Annual sprinkler, main drain, and antifreeze tasks: 365 days. Five-year internal pipe assessment: 1825 days.
- Emergency lighting, NFPA 101: monthly functional test of at least 30 seconds is 30 days. Annual full test of at least 90 minutes on battery is 365 days.
- UK presets: BS 5306-3 annual extinguisher service is 365 days. BS 5839-1 alarm servicing is 182 days. BS 5266 monthly flick test is 30 days. BS 5266 annual full rated duration is 365 days.
Worked date for an annual exit light. Last service 2 June 2026. Preset length 365 days. Next due 2 June 2027. The notices for that asset go out on 3 May 2027, 19 May 2027, 26 May 2027, 30 May 2027, and 1 June 2027. A monthly light test on the same floor stays a second asset at 30 days, so logging March does not push the annual.
US presets follow common NFPA patterns: NFPA 10 extinguishers, NFPA 72 alarms, NFPA 25 sprinklers, NFPA 101 emergency lighting. UK presets cover BS 5306-3, BS 5839-1 and BS 5266. Presets are a starting point. Your authority having jurisdiction sets the real intervals. Set the interval when you add each asset. FireCert Clock is not an AHJ and does not certify systems.
Your authority having jurisdiction can require a shorter or longer gap. Type that number on the asset. The preset is the starting point, not a ruling.
What a notice contains
Each notice is about one asset. The subject line carries the product name, the asset name, and either "is due in N days" or "is overdue". N is 30, 14, 7, 3, or 1.
The message names the asset, the building, and the due date. The next line is the task from the preset, or the asset type when no preset is selected, then the location. A blank location is written as not set. A link opens that asset.
The account email receives it. Up to five extra alert addresses on the account can receive the same note. From Starter, Slack and Teams receive the same subject and the same text. Client mail, also from Starter, repeats the note and adds that it was sent because that person is listed as the contact for the building. You do not edit those sentences. The calendar feed is a separate subscription of due work. It is not a second draft of the email.
FAQ
Do tags still go on the equipment?
Yes, where your code requires them. This product keeps the schedule and the paperwork.
Can the building contact get mail too?
Yes, from Starter. Add a client contact on the site.
What is on the site PDF?
Every asset, last service, next due and status, with uploaded certificates attached.
How do technicians see their work?
Each technician gets an iCal feed you can subscribe to in Google Calendar, Outlook or Apple Calendar.
How is the next due date worked out?
Add the interval, in days, to the last service date. Preset lengths are the NFPA and BS day counts listed above, including 30, 91, 182, 365, 7, 1825, 2190, and 4380. A number you type on the asset replaces the preset for that asset only.
What does the notice email say?
The asset name, the building, whether it is due in 30, 14, 7, 3, or 1 day or already overdue, the due date, the task, and the location, plus a link to the asset. Client mail adds that the recipient is listed as the contact for the building.
Can a facilities team use it without a contractor?
Yes. The same sites, assets, presets, and notices work when the people who occupy the building run the account.