England fire logbook for managing agents
Managing agents and Responsible Persons in England keep a log that is not an annual renewal and not a UK wide form.
HSE teams with many sites keep one confirmed date per building.
Managing agents get blamed for a fire door that was not checked, even when the height of the building means that particular 2022 duty does not apply, or when it does and the log is a binder in one of five blocks. The Fire Safety (England) Regulations 2022 apply in England. They are not a single yearly certificate. The fire risk assessment is reviewed regularly, on an interval you set. Communal fire doors in residential buildings over 11 metres are checked at least every 3 months. Flat entrance doors are at least every 12 months on a best endeavours basis. High rise residential buildings add monthly checks.
The sources are on the England fire safety logbook page. Checks that depend on height stay off until the building profile matches.
A block-by-block log
Add a site per building, not per portfolio. Set the height and whether there are residential common parts. Upload the last fire risk assessment or the door log. You review suggested dates and actions. A weekly alarm test and a monthly emergency lighting check are optional presets you turn on only if that is the interval you use. BS numbers are names, not a copied standard.
Corporate teams can read England fire dates for HSE teams. The agent index is property managers.
The agent's week is the log, the assessment, and the doors that actually apply
A managing agent in England is often the responsible person for the common parts, or one of several responsible persons who have to coordinate. GOV.UK, read 9 Nov 2026, says you are responsible if you are the employer, the owner, the landlord, the occupier, or anyone else with control, including a managing agent. You must carry out a fire risk assessment, review it regularly, keep a written record, maintain fire safety measures, plan for an emergency, and train staff. Scotland and Northern Ireland are different regimes. The page says so. https://www.gov.uk/workplace-fire-safety-your-responsibilities
The assessment page, read the same day, lists five steps and says review regularly. It does not give a renewal month. Article 9 of the Regulatory Reform (Fire Safety) Order 2005, as shown on legislation.gov.uk on 8 Nov 2026 and read 9 Nov 2026, says the responsible person reviews the assessment regularly so it stays up to date, particularly if it may no longer be valid or the premises have significantly changed, and records the findings. https://www.legislation.gov.uk/uksi/2005/1541/article/9
The Fire Safety (England) Regulations 2022 came into force on 23 January 2023. GOV.UK's overview, read 9 Nov 2026, requires quarterly checks of communal fire doors and annual checks of flat entrance doors in multi occupied residential buildings over 11 metres, monthly checks of firefighter lifts and essential firefighting equipment in high rise residential buildings (at least 18 metres or 7 storeys), and a report to the fire and rescue service if that equipment is out of order for more than 24 hours. Those duties are not the risk assessment review. A shop with no residential common parts does not pick them up from that instrument. https://www.gov.uk/government/publications/fire-safety-england-regulations-2022
Penalties on the GOV.UK enforcement page, read 9 Nov 2026: minor penalties up to £5,000. Major penalties can be unlimited fines and up to 2 years in prison. Appeals to the magistrates' court are within 21 days of a notice. https://www.gov.uk/workplace-fire-safety-your-responsibilities/enforcement-appeals-and-penalties
FireCert Clock stores the interval you set for the assessment review. It does not carry out the assessment, does not sign it, and does not send the 24 hour fault report.
Documents for the client report
The written fire risk assessment and the latest review note, the action list, the log of door checks where the building is tall enough, and the lift and equipment checks where it is high rise. Guides: England fire safety logbook, risk assessment review, fire door checks, logbook template. Upload: upload an England logbook.
Calculation: seven managed buildings, one agent login
Seven sites fit Starter's 10 and miss Free's 1. One seat fits Starter. If the seven buildings together hold 200 assets, that is inside 500 and far past Free's 25. Monthly price $39. Yearly $390, which is $39 times 10. Client email is included, so each landlord contact can get the reminder. A colleague who also needs a login moves the account to Pro at $79 a month, yearly $790, with 5 seats and 50 sites. All of those figures are on pricing. None of them is a new price.
Mistakes
Calling the assessment an annual renewal because a policy uses 365 days. That interval is yours. It is not a statutory birthday. Applying door frequencies to a commercial unit with no residential common parts. Telling a client the product filed a lift fault. It did not.
Corporate teams can read England fire dates for HSE teams.
Does the height band get proposed from the address?
No. You record whether the building is under 11 metres, over 11 metres, or high rise, and whether it has residential common parts. Those answers decide which checks the profile offers.
Can two responsible persons share one site?
The site stores one building. Note the other duty holder in the record. GOV.UK says responsible persons in shared premises have to coordinate. The product does not negotiate that split.
FAQ
Is the log renewed annually?
No. The risk assessment review interval is one you choose. Some door duties have their own minimums. Do not collapse them into one renewal.
Does this cover Wales or Scotland?
No. The 2022 regulations described here apply in England.