FireCert Clock

Fire safety log book alternative

Keep a book on site if the inspector wants one. Put the due dates on a list that emails you. One site and 25 assets at $0 a month.

A binder in the riser room is cheap and inspectors know it. It cannot mail anyone. It cannot travel to the other van. When the responsible person leaves, the handwriting leaves with them.

FireCert Clock does not ask you to throw the book away. It asks you to stop trusting the book as the only schedule.

What changes when the dates are on a list

Each asset has a last service and a next due. Reminders arrive 30, 14, 7, 3 and 1 day before it is due. The visit file sits on the asset. The site PDF is what you hand over when someone asks for proof. The book can still live on site as the on-paper copy.

Add a building, add extinguishers, panels, sprinklers and emergency lights, pick an interval preset or set your own, then upload the report after each visit. On Starter, AI reads service and next due dates from the PDF for you to confirm.

Where paper slips

Several buildings. Staff changes. A book that went missing. Monthly checks that were done and never written. An annual that hid behind a monthly page.

Contractors with multiple vans cannot carry every client's binder. Facilities teams inherit a shelf of binders with conflicting handwriting.

Paper also fails quietly when someone uses the wrong month tab or copies last year's date without updating the year.

Who this is for

Small fire protection contractors who already produce the inspection report and need the schedule plus reminders without a dispatch suite.

Building and facilities managers who own their own equipment and answer to an AHJ or insurer.

Anyone who wants NFPA-style interval presets as a starting point, then edits to match what the local authority actually enforces.

FireCert Clock is a scheduling and record-keeping tool. Interval presets are a starting point. Your authority having jurisdiction sets the real intervals.

Pricing to add the list

Free is $0 a month for 1 site and 25 assets with email reminders. Starter is $39 a month for 10 sites, 500 assets, client contact emails and AI date reading. Pro is $79 a month for 50 sites with no asset cap, five seats and branded client reports. Business is $149 a month with no site cap, 15 seats, API access and CSV export. Yearly billing is $390, $790 and $1,490, which is two months free.

Rollout beside the binder

Print the fire safety log book template from the templates library if the inspector expects paper on site.

Create the site in FireCert Clock and add each asset you already tag in the building.

Enter last service and next due, or upload last year's PDF and confirm dates on Starter.

Add the building contact on Starter if they should get the same ladder of notices.

Keep writing in the binder if required. Let the list send mail so the binder is not the only reminder.

Most missed inspections trace back to a single gap: the person who used to update the log left, and nobody else knew which assets were due that quarter. A shared register with repeating mail closes that gap even when the paper book stays in the cabinet for walkthroughs.

Intervals the binder smears together

A monthly visual on the NFPA 10 monthly visual preset is 30 days. Yearly cylinder maintenance on the matching NFPA 10 preset is 365 days. Hydrostatic tests and the six year internal sit on the other NFPA 10 presets and are not those two dates. A paper tab that mixes monthly initials with the yearly tag makes the yearly look done because someone wrote in the book last month. Put each task on its own asset. Your AHJ still sets the enforceable gap. The preset is only the start.

What to record in both places

On the page: location, month, initials, and any deficiency the walker saw. On the asset: the same location, the last service date, the next due date, and a scan or photo of that page or of the tag. The tag stays on the cylinder where your program requires it. The list is what sends mail when the book is in a locked room.

Who signs the book and the tag

Monthly visuals are often initialed by in-house staff. The yearly maintenance tag is signed by the qualified person who did that work. FireCert Clock does not replace either mark. Logging a visit on the asset, and only when the work passes, is what moves the next due date. A blank September page after a staff change is the gap the mail is there to catch.

How a copied year fails

Someone opens last year's annual line, writes the same day and month, and forgets to change the year. The book looks current. The cylinder is a year late. A book that rode away in a van, or a monthly that was performed and never written, fails the same way. Handwriting was the only schedule. The overdue list stays red until a passing visit is logged, even if a later page gets an initial.

Worked due date for cabinet C-3

Maple Elementary, cabinet C-3, NFPA 10 yearly maintenance interval, 365 days. Last maintenance 18 June 2025. Next due 18 June 2026. Notices reach the account on 19 May, 4 June, 11 June, 15 June and 17 June, the 30, 14, 7, 3 and 1 day marks before 18 June. From 18 June 2025 to 18 June 2026 the span does not include a leap day, so the preset lands on the same calendar day. The monthly visual for that cabinet, stored as 30 days, is a second asset. Its mail does not clear the June maintenance.

Binder and list as columns

RecordFireCert ClockPaper binder
Reminder before the dateEmail at 30, 14, 7, 3 and 1 day before dueDepends on someone opening the book
On the truckWeb app plus an iCal feedOnly if that van carried the binder
What an inspector can holdA site PDF, and the book if you still keep oneThe book, if it is still in the building
Price to start$0 a month for 1 site and 25 assetsThe cost of the book

FAQ

Can I print a log if I still want paper on site?

Yes. Use the fire safety log book template from the templates library, then keep the live dates in FireCert Clock.

Does the product replace tags?

Tags stay on the equipment where your code requires them. The list tells you which tags are coming due.

What reminders fire by default?

30, 14, 7, 3 and 1 day before each due date on every plan.

Can clients get email too?

Client contact email on a site starts on Starter at $39 a month.

Is payment required on Free?

No payment method on signup. One site, twenty-five assets, email reminders.

When paper still wins

Some inspectors want to see handwritten monthly checks in a physical book during a walkthrough. Keep the book for that ritual. Use FireCert Clock so the annual and the quarterly do not depend on someone remembering to flip pages.

Book and tag questions

Who initials the monthly line?

Usually the in-house walker. The yearly tag is a different signature, from the person who performed that maintenance.

What does cabinet C-3 need in the file?

Location, the June maintenance date, the next due date, and a photo or scan of the tag or the book page.

Why does copying last year's line fail?

The month looks right and the year is wrong. The list uses the date you confirmed, not the handwriting habit.

Set up a site free

Set up a site free