Which NSW Buildings Need an Annual Fire Safety Statement
The regulation's test is a building to which an essential fire safety measure applies. A council class list is that council's page, not a second rule.
An annual fire safety statement is required, under section 89(1) of the Environmental Planning and Assessment (Development Certification and Fire Safety) Regulation 2021, from the owner of a building to which an essential fire safety measure applies. The owner must give the council an annual fire safety statement for the building. AustLII's consolidation of section 89, read 13 Nov 2026, states a maximum penalty of 800 penalty units for a corporation and 400 penalty units for an individual. https://classic.austlii.edu.au/au/legis/nsw/consol_reg/epaacafsr2021839/s89.html
That is the statutory test. It is not a list of street addresses, and it is not a fee. NSW Planning, read 13 Nov 2026, describes the annual fire safety statement as a document issued by or on behalf of the owner of an existing building. It confirms that an accredited practitioner (fire safety) has assessed, inspected, and verified each fire safety measure that applies, and that the exit systems comply with the Regulation. https://www.planning.nsw.gov.au/the-planning-system/buildings/fire-safety-in-buildings/fire-safety-certification
FireCert Clock stores the building and the date you confirm. It does not decide the building class, lodge the statement, or tell a council that a house is exempt. Presets are a guide. Confirm the building with the council that will receive the statement.
What "an essential fire safety measure applies" means in the regulation
Section 81(1), on AustLII read 13 Nov 2026, says the owner of a building must maintain each essential fire safety measure for the building. If the measure is specified in a fire safety schedule, the standard is no less than the schedule. If the measure applies but is not specified in the schedule, AustLII's note calls it an original measure, and the standard is no less than that to which the measure was originally designed and implemented. The note on section 81 says some pre 1997 buildings may not have a fire safety schedule but essential fire safety measures still apply. The maximum penalty stated for section 81(1) is 600 penalty units for a corporation and 300 for an individual. https://classic.austlii.edu.au/au/legis/nsw/consol_reg/epaacafsr2021839/s81.html
Section 81(2) says the owner of a building to which an original measure applies may request from the council a schedule of the original measures. Section 81(3) says the council must provide that schedule as soon as practicable after the request. A missing schedule is not the same as a building with no measures. The request is how the regulation tells the owner to obtain the list.
NSW Planning, read 13 Nov 2026, says a fire safety schedule sets out the measures and the minimum standard of performance. From 1 August 2023 a new schedule uses the NSW Government template. Existing buildings do not have to use that template unless a new schedule is required. Where a council reissues a schedule because corrections are needed or the schedule is missing, Planning says the new template is not required unless it is already being used for the existing or replaced schedule.
Council class lists are not identical
North Sydney Council's annual fire safety statement page, read 13 Nov 2026, says all owners of buildings categorised Class 1b to Class 9 under the Building Code of Australia must submit an annual fire safety statement. The same page says Class 1a buildings do not need one. It gives single dwelling houses, terraces, and villa houses as Class 1a examples, and tells the reader to check the Building Code of Australia classifications if the class is unclear. https://www.northsydney.nsw.gov.au/getting-construction-underway/submit-annual-fire-safety-statement/print
Shoalhaven City Council's fire safety program, read 13 Nov 2026, says preparation and submission of an annual fire safety statement is mandatory for all buildings other than a class 1a or 10 building or a temporary structure. That exclusion adds class 10 and a temporary structure. It does not repeat North Sydney's Class 1b to Class 9 sentence. https://www.shoalhaven.nsw.gov.au/Development-and-business/My-business/Business-registration-and-inspections/Fire-safety-program
Use section 89 for the duty. Use the council page for how that council describes the buildings it expects to receive. If the two descriptions do not match the building in front of you, ask that council. Do not average the two class lists into a third rule.
Shoalhaven, on the same page, says there must be one annual fire safety statement per building. If one fire safety schedule covers multiple buildings, Shoalhaven still wants a separate statement for each building, naming which essential fire safety measures apply to each. Shoalhaven also says only one annual statement, listing all installed measures, is submitted to council and to Fire and Rescue, and displayed in the building. A separate statement for each measure is not what that page asks for. Critical measures on a shorter cycle are supplementary statements. Those are a different document. NSW Planning describes them as statements issued at the interval the schedule specifies for critical measures.
Vacant buildings and new work
Shoalhaven's fire safety program, read 13 Nov 2026, says all fire safety measures listed on the fire safety schedule, including egress paths and exits, must be maintained at all times even when the building is vacant. The same page says the owner maintains each essential fire safety measure whether the building is occupied or vacant. That is Shoalhaven's statement of the maintenance duty. It is not a fee and it is not a new interval.
A brand new building is not yet on the annual statement cycle in the way an existing building is. North Sydney, read 13 Nov 2026, says new developments require a final fire safety certificate issued as part of the occupation certificate process, and that the certificate serves in place of the annual fire safety statement for the first 12 months. A copy of the final fire safety certificate is displayed until the first annual statement is issued. Section 89(2), on AustLII read 13 Nov 2026, says the owner gives the annual statement within the later of 12 months after a previous annual statement was given, or, if a fire safety certificate has been issued within the previous 12 months, 12 months after the certificate was issued. The certificate and the statement are different documents. The certificate note is the NSW fire safety certificate.
What the owner still does after the building is in
Section 89(2) sets the time to give the statement. Section 89(3) says failure to give it within that time is a separate offence for each week the failure continues. Section 89(4) says that as soon as practicable after the statement is issued, the owner gives a copy of the statement and a copy of the current fire safety schedule to the Fire Commissioner, and ensures a copy of the statement and the current schedule are prominently displayed in the building. The maximum penalty stated for the display limb is 55 penalty units. Section 89(6) says that where the premises are in the Alpine Region under the named State Environmental Planning Policy, the statement goes to the Minister rather than the council.
NSW Planning, read 13 Nov 2026, says the statement must use the fire safety statement template. North Sydney, read the same day, says the same thing and points owners to the Department of Planning template. FireCert Clock does not host that template.
Shoalhaven, read 13 Nov 2026, says the required assessment and inspection must have been carried out within the three months before the date the statement is issued, and that the choice of person is the owner's, with that person inspecting and verifying each measure being assessed. Attribute that three month sentence to Shoalhaven. The accredited practitioner rules NSW Planning publishes are the ones to read before you treat a contractor as able to assess a measure. Planning's certification page is the link above.
Late fees are council fees. North Sydney publishes 1,000, 2,000, 3,000, and 4,000 dollar bands for weeks 1 to 4 on the page linked above. Shoalhaven publishes penalty notice amounts of 1,000 dollars for the first week, 2,000 for the second, 3,000 for the third, and 4,000 per week for the fourth and subsequent weeks, and says a Local Court maximum fine of 110,000 dollars may be imposed, and that failure to maintain an essential fire safety measure may attract an additional 6,000 dollar penalty notice. Those dollars belong to the council that printed them. They are not a statewide price list. Sydney council channels are on lodging an annual fire safety statement in Sydney.
Sydney, Newcastle, and the rest of the state
The section 89 duty is a New South Wales duty. It is not a City of Sydney by law and not a Newcastle by law. A building in Sydney uses the City of Sydney lodgement channel when that council is the one that receives the statement. A building in Newcastle uses Newcastle's channel. The class question is still section 89 plus the council's own description. Six Sydney councils, including North Sydney and The Hills, publish their own lodgement notes on the Sydney annual fire safety statement note. Baulkham Hills sits in The Hills Shire. That note is the council step. It does not replace the class test.
The working checklist is requirements for an NSW annual fire safety statement. The date count is when the NSW annual fire safety statement is due. The template contents are what to include in an NSW annual fire safety statement.
Upload the schedule and we fill it in for you
Upload the fire safety schedule or the last annual fire safety statement. FireCert Clock suggests the measures and dates printed on that file. You accept all suggestions or edit one field. Each suggestion names the file and the page. Nothing is lodged with a council from the upload. The steps are on upload last year's NSW annual fire safety statement.
The state overview is the NSW annual fire safety statement.
Regulation test and two council descriptions
| Feature | What it decides | What it does not decide |
|---|---|---|
| Section 89, AustLII, read 13 Nov 2026. https://classic.austlii.edu.au/au/legis/nsw/consol_reg/epaacafsr2021839/s89.html | The owner of a building to which an essential fire safety measure applies gives the council an annual fire safety statement | A class number, a fee, or a Sydney only rule |
| North Sydney Council, read 13 Nov 2026. https://www.northsydney.nsw.gov.au/getting-construction-underway/submit-annual-fire-safety-statement/print | That council says Class 1b to Class 9 must submit, and Class 1a houses, terraces, and villa houses do not | Shoalhaven's class 10 line, or another council's channel |
| Shoalhaven City Council, read 13 Nov 2026. https://www.shoalhaven.nsw.gov.au/Development-and-business/My-business/Business-registration-and-inspections/Fire-safety-program | That council says the statement is mandatory for all buildings other than class 1a, class 10, or a temporary structure, and one statement per building | North Sydney's late fee table |
Does a pre 1997 building without a schedule skip the statement?
Section 81's note says some pre 1997 buildings may not have a fire safety schedule but essential fire safety measures still apply. The owner can request a schedule of original measures from the council. Section 89 still uses the "measure applies" test.
Is a fire safety certificate the document these buildings issue every year?
No. NSW Planning describes the certificate for completed new building work and the statement for an existing building. See NSW fire safety certificate and the annual statement.
FAQ
Does FireCert Clock classify the building?
No. You confirm whether an essential fire safety measure applies, using the schedule, section 81, and the council that receives the statement.
Are North Sydney's class words the rule in Shoalhaven?
No. Each sentence above is tied to the council that published it. Section 89 is the duty that applies in both places.
Where do Sydney lodgement steps live?
On lodging an annual fire safety statement in Sydney, for the six councils that note covers. The class test is still section 89.