England fire dates for HSE teams
An England portfolio is a set of Responsible Person duties. The review is regular. It is not automatically yearly.
Property and strata managers keep a log per building.
HSE teams covering England are often asked for "the annual fire risk assessment renewal". GOV.UK describes a regular review, not a fixed renewal. The Fire Safety (England) Regulations 2022 then add checks that turn on only for residential buildings over 11 metres, and further monthly checks for high rise residential buildings. A head office template that ticks every row for a two storey office invents duties. A template that ticks none of them misses a residential block over 18 metres.
The log and the sources are on the England fire safety logbook page. FireCert Clock does not send a fault report to a fire and rescue authority. A fault not fixed within 24 hours is a record for you to report.
Many English sites
One site per building. Record the height band and the common parts flag so the matching checks switch on. Upload the assessment. You review the suggested review date and the actions. Leave the review interval as the number your competent person actually uses. Sites in Scotland or Wales are not given this preset.
Managing agents who hold the log can use England fire logbook for managing agents. The team index is HSE teams.
Many sites, and almost none of them share a renewal month
An HSE team with English buildings cannot run one fire calendar and call it the Fire Safety Order. GOV.UK, read 9 Nov 2026, requires the responsible person to review the fire risk assessment regularly. Article 9 tells you when a review is particularly required: the assessment may be invalid, or there has been a significant change. It does not say every 12 months. A company standard of 365 days is allowed only as your own interval, confirmed by you.
Residential blocks add dated checks from the Fire Safety (England) Regulations 2022, in force 23 January 2023. Over 11 metres with common parts: communal fire doors at least every 3 months, flat entrance doors at least every 12 months. High rise, at least 18 metres or at least 7 storeys: monthly checks of lifts for firefighters and of essential firefighting equipment, and a duty to tell the fire and rescue service if a fault lasts more than 24 hours. GOV.UK states those duties. https://www.gov.uk/government/publications/fire-safety-england-regulations-2022
The team records the check. The team does not send the fault notice by saving a row. Penalties GOV.UK states, read 9 Nov 2026, include fines up to £5,000 for minor cases and, for major cases, unlimited fines and up to 2 years in prison. https://www.gov.uk/workplace-fire-safety-your-responsibilities/enforcement-appeals-and-penalties
Audit columns
| Feature | Risk assessment review | Communal fire doors | Flat entrance doors | Firefighter lifts and equipment |
|---|---|---|---|---|
| Who | Responsible person | Responsible person, in multi occupied residential buildings over 11 metres | Responsible person, in those same buildings | Responsible person, in high rise residential buildings |
| Interval you store | The number of days you choose. Blank means no countdown | At least every 3 months where the duty applies | At least every 12 months where the duty applies | Monthly, where the duty applies |
| Evidence | Written assessment and review findings | Check record | Check record, including access attempts when a door was not reached | Check record, and your own note if a fault passed 24 hours |
| What the product refuses | Writing the assessment | Deciding the building is over 11 metres | Filing anything with the fire authority | Sending the 24 hour report |
Guides: logbook, review, doors, template. Upload: upload an England logbook. Managing agents: England fire logbook for managing agents.
Calculation: 40 English sites and four logins
Forty sites miss Pro? No. Pro allows 50 sites. Four seats fit Pro's 5. Monthly price $79. Yearly $790, which is $79 times 10. Starter stops at 10 sites and 1 seat, so it does not fit. Business at $149 a month is for more than 50 sites, more than 5 seats, or the API. The overdue list and the activity export exist before that. See pricing. This is a calculation from that table.
Set the review interval per building. A warehouse that changed layout needs a review because article 9 says so, even if your 365 day row is not due. Record the trigger in the notes. The action register is not an enforcement notice.
Misses
Marking every site as high rise. Copying a residential door preset onto an office. Treating Scotland's regime as if the England regulations covered it. GOV.UK points to different rules for Scotland and for Northern Ireland. Confirming a suggested date from a scan that is the contractor's service sheet rather than the assessment review.
Is a blank interval a failure?
It means you have not chosen a countdown. The legal duty to review regularly still sits with the responsible person. An empty countdown stays empty until you choose one.
Do weekly alarm tests come from the Order?
The weekly alarm row and the emergency lighting rows are optional presets you can edit. BS 5839-1 and BS 5266 are named only. Type the interval you actually use.
FAQ
Who is the Responsible Person in the profile?
The field stores the name you enter. It does not decide the legal Responsible Person. That is the person the fire safety order identifies for the premises.
Do monthly lift checks apply to every office?
No. They apply to high rise residential buildings, 18 metres or at least 7 storeys, under the England regulations described on the logbook page.