Kitchen suppression inspection
A restaurant hood certificate is a dated asset. Put the system on the site, upload the last ticket, and get reminded before the next service.
Commercial kitchen hood suppression fails inspections when the last service ticket lives in a drawer by the fryer. The fire marshal asks for dates. Facilities guesses. Treat the suppression system as a dated asset with its own interval, location, and paperwork trail.
What belongs on the asset list
Wet chemical system. Cylinders, nozzles, fusible links, and the service tag from the last visit.
Exhaust cleaning. Grease duct cleaning is often on a different cycle than cylinder service. Split assets so a late hood clean does not hide an overdue cylinder.
Manual pull and gas shutoff. Some jurisdictions expect these checked on the same visit as the system.
Contractor vs in-house. If you hold the service contract, you own the dates. If a vendor holds it, add them as a client contact on Starter so they get reminder mail.
FireCert Clock is a due-date tracker. It does not certify systems and it is not an authority having jurisdiction. Confirm intervals with your AHJ and the manufacturer manual.
Typical intervals
Many kitchens see semiannual service on suppression hardware. High-volume cooking can be tighter. Low-use sites may differ. NFPA 17A and NFPA 96 inform many US programs, but your AHJ wins over a blog default.
Set the interval when you add the asset for the cycle you actually run.
After the technician leaves
Upload the ticket PDF or photo. On Starter and above, FireCert Clock reads service dates from the report and you confirm the next due. Notices email you at 30 days, 14 days, 7 days, 3 days, and the last day. Add the kitchen manager as a client contact on Starter if they need the same mail.
Free is $0 a month for 1 site and 25 assets with email reminders. Starter is $39 a month for 10 sites, 500 assets, client emails, and AI date reading from uploaded reports. Pro is $79 a month for 50 sites with no asset cap and branded PDFs. See pricing for Business limits.
Proof for insurers and brands
Franchise and property insurers increasingly ask for digital proof. The site PDF lists every asset, last service, next due, and status, with certificates attached. Hand that PDF to the building manager before the walk.
Split tasks that hide each other
One row named "kitchen hood" buries a five-year internal on a dry system elsewhere in the building. Create an asset per task you actually own.
Who should get reminders
Facilities should always receive mail. Kitchen managers often need the same dates as the contractor. Client contacts on Starter copy notices without forwarding screenshots.
Technicians can subscribe to iCal feeds for upcoming hood work across sites.
What the ticket should record
Write the hood or system name, the cooking line it covers, cylinder serials, nozzle count, whether fusible links were replaced, the manual pull result, the gas shutoff result, the technician name printed on the ticket, and the service date. Exhaust cleaning stays a second asset when the duct cycle is not the cylinder cycle. A phone photo of the tag is enough until the full PDF arrives. On Starter you confirm the dates read from that upload.
Who signs the hood work
The service company that performed the visit signs the ticket. A kitchen manager added as a client contact on Starter receives the same dates on the line. That contact does not become the signer. FireCert Clock stores the file. It does not certify the system, and it does not replace the manufacturer manual or your authority having jurisdiction.
Intervals to set before the fryer lineup changes
Many kitchens run suppression hardware about twice a year. If you store that cycle as 182 days, that number is twice the 91 day quarterly gauge interval already used on sprinkler assets. NFPA 17A and NFPA 96 are the names many US programs look up. They are not a substitute for the interval your AHJ or the manufacturer already wrote into the service contract. High-volume frying can be tighter. A low-use banquet kitchen can be longer. Change the stored interval after the inspection that documents the new volume.
Failures that hide a red cylinder
One row labeled kitchen hood lets a late grease-duct clean mask an overdue cylinder. Fusible links get painted during a hood remodel. A speed rack blocks the manual pull. The account manager changes and last year's PDF stays in the old inbox. Split the assets, and keep the contractor as a client contact, so those misses show as separate rows.
Worked due date for hood K-2
Dockside Grill, hood K-2, interval stored as 182 days. Last ticket 9 January 2026. The next due date is 10 July 2026. Mail for that asset goes out on 10 June, 26 June, 3 July, 7 July and 9 July, the 30, 14, 7, 3 and 1 day marks before 10 July. If July passes with no passing visit logged, the row stays overdue. A duct-clean asset with a different last date does not move this cylinder date.
Grease-duct cleaning stays on a second asset, with an interval you can point to on a certificate. That split is kitchen hood cleaning frequency.
FAQ
Can I track cleaning and suppression on one row?
You can. Two assets keep a late clean from hiding a cylinder date.
Does the product issue the hood certificate?
You upload the certificate the service company issued.
What if my vendor already reminds me?
Vendors miss mail too. Your list is the backstop when the account manager changes.
Can I import many locations?
Yes. CSV import with site, type, location, and last service.
Is semiannual always correct?
No. Confirm with your AHJ and manufacturer. Set the interval when you add the asset.
Does FireCert Clock dispatch technicians?
No. It tracks dates and stores paperwork. Your licensed contractor still performs service.
Franchise and multi-site operators
Load each restaurant as its own site when regions differ. Corporate safety can download each site's PDF on any plan before unannounced visits; Pro adds your branding. Kitchen managers see the same dates as facilities when you add client contacts on Starter.
Photos and partial tickets
Phone photos of service tags still upload when the full PDF arrives later. Confirm dates after upload on Starter so the next due moves forward the same day.
Insurance renewals
Property insurers ask for suppression service dates with extinguisher records. The combined site PDF answers both without merging spreadsheets the night before renewal.
Seasonal menus
When kitchens add fryers or change volume, revisit intervals after the next inspection rather than waiting for a failed tag.
Hood sign-off questions
Who signs the suppression ticket?
The contractor who serviced the hood. Uploading the PDF does not transfer that signature into the software.
Which fields belong on the hood asset?
System name, cooking line, cylinder serials, nozzle count, link replacement, pull and shutoff results, technician name, and service date.
Can a late duct clean clear the cylinder?
No. Two assets keep those dates apart. Logging the clean moves only the clean.
Support and Terms. Calculator.